piston size dimensions shipping information cabinet width (w)” cabinet depth (d)” cabinet height (h)” shipping weight (lbs) skid r22 r410a min width max width 2 row 3 row 4 row qty de24a* 0.059 0.055 142 21 21 1/2 19 33 36 41 20 de24b* 0.059 0.055 142 21 21 1/2 19 36 39 45 20 de24c* 0.059 0.055 142 21 21 1/2 23 40 46 50 16When you add a matching evaporator coil to your system, you get complete home comfort, peak performance and maximized efficiency. Allied Air Enterprises Armstrong Air® Evaporator Coil, Traditional, Series: EC1P-1, 4 ton Nominal Capacity, 1200 to 2000 cfm, Upflow/Downflow Air Flow Type, R-22/R-410A, Piston Expansion Metering Device, 3/8 …Page 18 14SEER R410A HP Charge Chart 4 TON(Cooling mode) Outdoor Ambient Temperature ... Matching table and Checkout Procedures 18.1 Matching table If Preinstalled Piston Condensing Unit Air Handle / A-Coil Piston Size / TXV Valve Model SEER Replace Required J4AH4P18A1A00AA 0.050/(4AYTXVH3G2436A) J4AH4E24A1A00AA …

Did you know?

Manuals and buying guide for Comfortmaker - FEM4P3600A - Piston Air Handler R410A, 3 Ton, Copper Tube, Aluminum Fin Evaporator. Find specifications on Comfortmaker FEM4P3600A. Hotline Free: (888) 882-4424Chrome/Firefox/Opera/Safari: If you're unhappy with Facebook's new small font size (or other annoyances), userscript Better Facebook gives you over 75 extra options with which you ...These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem.The coil is rated for the higher pressure of R410A, but will work with R22, as well. If using R22 refrigerant, use a #59 piston. If going with Puron (R410A), take the piston out and install a TXV rated for a two ton system with R410A. There is no piston for R410A on this coil, you need to install a TXV. Tim H. Category: HVAC.Product Description. Features. 10 year warranty on parts & compressor High efficiency scroll compressor. Direct drive multi-speed PSC indoor motor. All aluminum evaporator coil Designed for upflow, downflow, horizontal left and horizontal right installations. Condenser pre-charged with R-410A refrigerant. Insulated air handler cabinet.Goodman GPH1348H41 - Goodman 4 Ton 13 SEER Packaged Dedicated Horizontal Heat Pump, R-410A Refrigerant- The Goodman® GPH13H 13 SEER Package Heat Pump provides energy-efficient cooling and heating performance in one self-contained unit. The Goodman GPH13H is housed in a heavy-gauge, galvanized-steel cabinet that …ADP 100000039 - Piston .67, 2 1/2 Ton R22, 3 Ton R410APiston Size 67. Can be used on 2 1/2 Ton R22 Coil or 3 Ton R410a Coil. The store will not work correctly in the case when cookies are disabled. Due to scheduled maintenance, some website features will be unavailable on Saturday 10/29. ...4 to 5 ton evaporator coil. Installable in the horizontal configuration. Usable with either a heat pump or an AC-only condenser. Works with R410A or R22 refrigerant. Low air leakage. Check flowrater expansion device for use in any application. 4 to 5 Tons. At an output of 4 to 5 tons, the Goodman CHPF4860D6 evaporator coil is ready for almost ...INSTALLATION INSTRUCTIONS R−410A Split System Air Conditioner 4 421 01 5301 01 UNIT SUPPORT NOTE: Unit must be level ... Check piston size shipped with indoor unit to see if it ... FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench. Hand tighten hex nut, then tighten with wrench 1/2 turn. …Problem is I cant find any info on sizing of Rheem's pistons or the coil. Any help would be appreciated.” The Rheem air handler Model number told us that the 48 was for the BTU rating(4 ton as BaldLoonie pointed out) and the 82 stood for the piston size(as BaldLoonie pointed out as well).Manuals and buying guide for Comfortmaker - FEM4P3600A - Piston Air Handler R410A, 3 Ton, Copper Tube, Aluminum Fin Evaporator. Find specifications on Comfortmaker FEM4P3600A. Hotline Free: (888) 882-4424Be the first to ask a question about this product! Product Features. Product DetailsLennox Elite C35, C35-49C-2, 4 Ton, Piston (R410A), Uncased Aluminum Upflow Evaporator Coil. Cat # : 16F44. Model/Part # : C35-49C-2. Replacement Available This product has been replaced by Cat# ... 4 Ton . Metering Device. Piston (R410A) Product Depth. 21.5 Inch . Product Width. 19.5 Inch . Product Height. 28.5 Inch . Cased. …R-410A environmentally friendly refrigerant. System Size (Tons): 4 ... you need to throw out your old air conditioner that hasn’t kept you cool in ages and switch it out with the ProDirect 4 Ton 15 SEER Split System A/C Condenser from MRCOOL. ... the piston flow control device manages the speed and volume of the refrigerant as it runs to ...14 seer split system air conditioner & heat pump 1.5-5 tons r410a (24 pages) Air Conditioner Trane Voyager Manual. Product (93 pages) ... * The ship-with literature bag will contain additional Outdoor Unit Piston Size* R-410A pistons for most applications. Piston Kit Capacity (Tons) (R410a) * Contact your local parts center to order the ... ADP - 176799976 - 4 Ton Piston Size 76 R-22/R-410A. Item: ADP176799976 . MFG: 176799976 Apr 25, 2017 ... ... 410a charging chart can help you fix your ... The orifice size in the piston determines how much liquid refrigerant enters the evaporator coil.Mar 19, 2011 · Existing equipment is a 4 ton 10 seer r-22. If a 3.5 ton 14 seer 410a is installed in its place, does the seer make up for the 1/2 ton? … read more. Apr 3, 2016 · Post Likes. Originally Posted by rsmith46. Use this easy formula to charge a piston R22 system by super-heat. WB times 3 minus OD temp minus 80 times 2. WB* x 3 -OD* - 80 x 2. I don't know of a formula for figuring the target SH on 410a, since only Goodman uses pistons. Thats my problem. It is the same. Be the first to ask a question about this product! Product Features. Product Details

Available for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separatelygoodman piston size. I bought some left over r22 goodman 13 seer condensor units. A gsc 2 ton and a 2 1/2 ton. Neither of these units had their customary piston connected to the condenser under the electrical panal. I decided to look online and get the piston size but under piston size for these 2 units just have a slash.piston kit chart outdoor goodman indoor piston outdoor goodman indoor piston section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. …INSTALLATION INSTRUCTIONS R−410A Split System Air Conditioner 4 421 01 5103 00 UNIT SUPPORT NOTE: Unit must be level ... Check piston size shipped with indoor unit to see if it ... FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench. Hand tighten hex nut, then tighten with wrench 1/2 turn. … Manuals and buying guide for Comfortmaker - FEM4P3600A - Piston Air Handler R410A, 3 Ton, Copper Tube, Aluminum Fin Evaporator. Find specifications on Comfortmaker FEM4P3600A. Hotline Free: (888) 882-4424

*Heat Strip Size *Copper Refrigerant Line Set: Clear: 2.5 Ton Oxbox by Trane R410A Multi-Position Standard Efficiency Air Handler quantity. Add to cart. Compare SKU: J4AH4P30A1B00AA ... 4 Ton Goodman 15.2 SEER2 R410A Single Stage Heat Pump Split System. Rated 5.00 out of 5 $ 4,547.10 – $ 5,109.10-Brand New HEIL 2.5 Ton R-410A Piston Air Handler Multi-Position Aluminum 208/230/1 Model# FEM4P3000AL #BSP1 ... Refrigerant Type R-410A Liquid Line Size 3/8 in Suction Line Size 3/4 in Filter Size 16-3/8 x 21-1/2 in Motor Type ECM Motor Rating 1/3 hp Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D ...…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Trane 4MXCD010AC6HCA 4MXC 24-1/2 in. 3.5. Possible cause: 20-ton product line has been designed for use only with R-410A and POE o.

Jul 16, 2021 · As the efficiency goes up pressure difference drops. 410 carries more BTU's /LB than 22. When you add all those up it could come out the same. In other words it takes a certain size orifice to move X lb of R-22 equal to Y BTU and that same size orifice just happens to move the right amount of R-410a because the efficiency of the system creates ...

3/8 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) For Heat Pump systems, the chart below shows when an application is considered Long Line. HP WITH R−410A REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above IndoorADP Nominal 4 Ton, Upflow/Downflow 17.5" Wide L15 A-Coil, Aluminum, Non-Bleed TXV. Item. ... • Piston options include externally accessible body for easy piston change out and/or TXV installation. ... and E65 for size 42 models and higher. • Dual 3/4" FPT condensate drains on front-left and front-right side of drain pans.Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil.

3. Remove the piston from the mechanical fittin CAUF4860C6 20" 28" 25" 4-5 ⅜" ⅞" .093 48 CAUF4860D6 23" 28" 25" 4-5 ⅜" ⅞" .093 39 CAUF4961C6 20" 28" 25" 4-5 ⅜" ⅞" .093 54 CAUF4961D6 23" 27" 25" 4-5 ⅜" ⅞" .093 59 * Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit. This Guideline covers all residential splitPiston fancoils are no longer offered in the 5 ton size; therefore n Advertisement We don't often realize how much untapped energy exists all around us. The principle behind these manhole explosions is similar to how a car engine works. Imagine a ci... Johnson Controls Ducted Systems Technical Rheem Air Handler. FORM NO. H11-545 REV. 1. RHBL- Series. X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series. PSC Motor Efficiencies up to 14.5 SEER. † Front or Bottom Return † Flow Check Piston for cooling or heat pump operation † Wall-hanging brackets † Built in Filter Rack † AHRI Certified † UL Certified † Molex Plug ...Check piston size shipped with indoor unit to see if it matches required indoor piston size. If it does not match, replace indoor piston with correct piston size in table below: piston kit chart outdoor goodman indoor piston outdoor gInsulated air handler blower & coil compartments. Condenser Technical Information. Suction Line Size—Evaporator to C What piston size for Goodman SSX140421A/ARUF 374316- 3.5 ton 14 seer R410a? - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... Existing equipment is a 4 ton 10 seer r-22. If a 3.5 ton 14 seer 410a is installed in its place, ... Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditi Rheem 4 ton 16 seer split system w/410a R22/410 system Refrigeration dupont handbook piping I have a rheem 80 plus model number rgdc-10ncbjr. the exhaust blower Goodman piston size chart r22Checking the charge on a heat pump in the winter R410a charging chartRheem hvac ac b702 9ce1 4acf. A tech could do a poor job of installing the R22 condenser and [Liquid Line Size: 3/8 in Metering Device: Piston MoIs your A/C System in need of repair or s 3.5 Ton, 4 Ton : Product Width (in) 17.5 : Line Set Connection Type: Sweat : Liquid Line Size: 3/8 inch : Weight (lbs) 66.000000 : Refrigerant: R-410a : Suction Line Size: 7/8 inch : Warranty: 5 Year Parts, 10 Year Evaporator Coil: California Residents: see Prop 65 WARNINGInformation from R410A 13 SEER AC/HP document ©2016 Ingersoll Rand Note: All match ups must be confirmed through AHRI. Condensing Unit Air Handler Piston Size Optional TXV Kit SEER If Preinstalled Piston Replace Required AC M4AC3018B1000NA M4AH3018B100AA C050 MAYTXVACAC1818AA 13 YES